·ÎµùÁß

LOADING...

À¯·Î½æµå¶óÀ̺ê DC DRIVE

590+Àº DC µå¶óÀ̺êÀÇ ¼¼°è¿¡ »õ·Î¿î °³³äÀ» µµÀÔÇÕ´Ï´Ù. DRV´Â ÆÐÅ°Áö Áß¿¡¼­ ¿¬ÇÕµÈ Èû ºÎºÐµéÀ» ¸ðµÎ Æ÷ÇÔÇÑ ´Ü ÇϳªÀÇ ÅëÇÕ ¸ðµâÀÔ´Ï´Ù. ÀÌ Çõ½ÅÀûÀÎ Á¢±ÙÀº ±Ùº»ÀûÀ¸·Î °¨¼ÒÇÕ´Ï´Ù. ¹è¼±½Ã°£°ú ºñ¿ë, DRV °³³äÀº À¯ÀÏÇÑ °Í, ±×¸®°í °æÇèÀ¸·ÎºÎÅÍ ÀϾ ±× Çõ½ÅÀûÀÎ µðÀÚÀÎÀÌ »ê¾÷ÀÇ ´Ù¾çÇÑ ¹üÀ§¸¦ °¡·ÎÁö¸£´Â ¼º°øÀûÀÎ Àû¿ëÀÇ ¼öõÀ¸·ÎºÎÅÍ Áõ´ëÇÏ¿´´ø Äè°ÅÀÔ´Ï´Ù.

Á¦Ç°Æ¯¼º

590+Àº ÃÖÁ¾ÀûÀÎ ½Ã½ºÅÛ µå¶óÀ̺êÀÌ°í, °¡Àå ¸¹Àº ÇÕ¼º¹°ÀÇ °¡È¤ÇÑ ¿ä±¸µé¿¡ ´ëóÇÏ´Â °ÍÀ» µðÀÚÀÎÇÏ¿´°í ±×¸®°í ±Ëº¯À¸·Î ¼Ó¿©Áø, ´Ù±â´ÉÀÌ »ê¾÷ÀÇ Àü¹ÝÀûÀÎ ¹üÀ§¸¦ °¡·ÎÁú·¯ Àû¿ëÀ» À¯µµÇÕ´Ï´Ù. ¸ðµç ´ÙÀ½ ±â´ÉÀº ¾î¶°ÇÑ ºÎ°¡ÀûÀÎ Çϵå¿þ¾î¿¡ ´ëÇÑ ÇÊ¿ä ¾ø´Â Ç¥ÁØÀ¸·Î½á »ç¿ë °¡´ÉÇÕ´Ï´Ù.

  • ÇÁ·Î±×·¥ Æã¼Ç ºí·Ï
  • Software Configurable I/O
  • ³ôÀº ºÐÇØ´É(12Bit)ÀÇ ¾Æ³¯·Î±× ÀԷµé
  • ¿ÍÀδõ Á¦¾î - Open loop with inertia compensation, Closed loop speed or current, Load cell / dancer process PID.
  • ¼öÁ÷ ¿¬»ê ±â´Éµé
  • ·ÎÁ÷ ±â´Éµé
  • ±âº»ÀûÀÎ Çʵå Á¦¾î
  • "S"·¥ÇÁ¿Í µðÁöÅÐ ·¥ÇÁ

Á¦Ç°»ç¾ç

  • CE Marked to EN50178 (Safety, Low Voltage Directive)
  • EN50081-2(1992)
    (EMC emissions, industrial environment with external filter fitted)
  • EN50082-2(1995) (EMC emissions, industrial environment)
  • UL listed to US and Canadian safety standard UL508C(uo to 720A)
  • North American safety standards pending > 720A.
  • Motor Over Temperature
  • Thyrister Trigger Failure
  • Interline Snubber Network
  • Zero Speed Detection
  • Standstill Logic
  • Stall Protection

590+ µðÁöÅÐ DC µå¶óÀ̺ê > 1~2000HP

  • 1¿¡¼­ 400HP
  • UL to 300HP
  • »ï»ó ÀÔ·Â
  • 230~480V
  • Ŭ·¡½Ä ½ºÅ¸ÀÏ

SPECIFICATION

Ratings

Power Configuration590+ Four Quadrant Regenerative
2 Fully Controlled Three Phase Thyristor Bridges
591+ Two Quadrant Non-Regenerative
1 Fully Controlled Three Phase Thyristor Bridges
Thyristor Controlled Variable Field Supply
Armature Current Ratings(Adc)13, 35, 40, 70, 110, 165, 180, 270, 360, 450, 720, 1200, 1700, 2200, 2700A(DRV versions available 1 - 165A)
Over load(15~450A) : 200% for 10secs, 150% for 30secs
Various optinal over load >= 720A
Armature VoltageV armature = Vac x 1.2
AC Supply Voltage (Vac)110~220V (¡¾10%)
220~500V (¡¾10%)
500~690V (¡¾10%) (>= 200A)
ÀÔ·Â ÁÖÆļö : 50 / 60Hz
Field Current4A (15~35A Á¤°Ý)
10A (40~270A Á¤°Ý)
20A (360~720A Á¤°Ý)
60A (>=1200A Á¤°Ý)
ÇʵåÀü¾ÐV field = Vac x 0.9
¾Æ³¯·Î±× ÀÔ·Â12ºñÆ® + ½ÅÈ£ ÃÑ 5°³ ÀÔ·Â
¼Óµµ Áö·ÉÄ¡ 1°³ ÀÔ·Â(-10/0/+10V)
º¯°æ °¡´ÉÇÑ 4°³ ÀÔ·Â
¾Æ³¯·Î±× Ãâ·Â10ºñÆ® ÃÑ 3°³ Ãâ·Â
¾Æ¸¶Ãß¾î Àü·ù Ãâ·Â 1°³ (-10/0/+10V or 0 -10V)
º¯°æ °¡´ÉÇÑ 2°³ Ãâ·Â
µðÁöÅÐ ÀÔ·Â24vdc ÃÖ´ë ÃÑ 9°³ ÀÔ·Â
ÇÁ·Î±×·¥ Á¤Áö 1°³
¾ÈÀü Á¤Áö 1°³
¿ÜºÎ Á¤Áö 1°³
°¡µ¿/Á¤Áö 1°³
º¯°æ °¡´ÉÇÑ 5°³ ÀÔ·Â
µðÁöÅÐ Ãâ·Â3 Total - 24V(max 30V) 100mA
Short circuit protected
3-Configurable
Reference Supplies1 - +10V dc
1- -10V dc
1- +24V dc
Optional Environment(6051) Operator / Programming Controller
Feedback Boards : Tachogenerator, Encoder, Glass Fiber Microtach, Plastic Fiber Microtach
Serial Communication Technology BoxProfibus DP
Devicenet
Canopen
Link
EI Bisynch / Modbus / RS422 / RS485

Environment

Ambient Operating Temperature0~45¡É (15~165A Ratings)
0~30¡É (180~720 A Ratings)
0~40¡É (>=1200 A Ratings)
ProtectionHigh Energy MOV's
Instantaneous Over current
Inverse Time Over current
Field Failure
Speed Feedback Failure
Motor Over Temperature
Thyrister Trigger Failure
Interline Snubber Network
Zero Speed Detection
Standstill Logic, Stall Protection