À¯·Î½æµå¶óÀ̺ê
DC DRIVE
590+Àº DC µå¶óÀ̺êÀÇ ¼¼°è¿¡ »õ·Î¿î °³³äÀ» µµÀÔÇÕ´Ï´Ù. DRV´Â ÆÐŰÁö Áß¿¡¼ ¿¬ÇÕµÈ Èû ºÎºÐµéÀ» ¸ðµÎ Æ÷ÇÔÇÑ ´Ü ÇϳªÀÇ ÅëÇÕ ¸ðµâÀÔ´Ï´Ù. ÀÌ Çõ½ÅÀûÀÎ Á¢±ÙÀº ±Ùº»ÀûÀ¸·Î °¨¼ÒÇÕ´Ï´Ù. ¹è¼±½Ã°£°ú ºñ¿ë, DRV °³³äÀº À¯ÀÏÇÑ °Í, ±×¸®°í °æÇèÀ¸·ÎºÎÅÍ ÀÏ¾î³ ±× Çõ½ÅÀûÀÎ µðÀÚÀÎÀÌ »ê¾÷ÀÇ ´Ù¾çÇÑ ¹üÀ§¸¦ °¡·ÎÁö¸£´Â ¼º°øÀûÀÎ Àû¿ëÀÇ ¼öõÀ¸·ÎºÎÅÍ Áõ´ëÇÏ¿´´ø Äè°ÅÀÔ´Ï´Ù.
Á¦Ç°Æ¯¼º
590+Àº ÃÖÁ¾ÀûÀÎ ½Ã½ºÅÛ µå¶óÀ̺êÀ̰í, °¡Àå ¸¹Àº ÇÕ¼º¹°ÀÇ °¡È¤ÇÑ ¿ä±¸µé¿¡ ´ëóÇÏ´Â °ÍÀ» µðÀÚÀÎÇÏ¿´°í ±×¸®°í ±Ëº¯À¸·Î ¼Ó¿©Áø, ´Ù±â´ÉÀÌ »ê¾÷ÀÇ Àü¹ÝÀûÀÎ ¹üÀ§¸¦ °¡·ÎÁú·¯ Àû¿ëÀ» À¯µµÇÕ´Ï´Ù. ¸ðµç ´ÙÀ½ ±â´ÉÀº ¾î¶°ÇÑ ºÎ°¡ÀûÀÎ Çϵå¿þ¾î¿¡ ´ëÇÑ ÇÊ¿ä ¾ø´Â Ç¥ÁØÀ¸·Î½á »ç¿ë °¡´ÉÇÕ´Ï´Ù.
- ÇÁ·Î±×·¥ Æã¼Ç ºí·Ï
- Software Configurable I/O
- ³ôÀº ºÐÇØ´É(12Bit)ÀÇ ¾Æ³¯·Î±× ÀԷµé
- ¿ÍÀδõ Á¦¾î - Open loop with inertia compensation, Closed loop speed or current, Load cell / dancer process PID.
- ¼öÁ÷ ¿¬»ê ±â´Éµé
- ·ÎÁ÷ ±â´Éµé
- ±âº»ÀûÀÎ Çʵå Á¦¾î
- "S"·¥ÇÁ¿Í µðÁöÅÐ ·¥ÇÁ
Á¦Ç°»ç¾ç
- CE Marked to EN50178 (Safety, Low Voltage Directive)
- EN50081-2(1992)
(EMC emissions, industrial environment with external filter fitted) - EN50082-2(1995) (EMC emissions, industrial environment)
- UL listed to US and Canadian safety standard UL508C(uo to 720A)
- North American safety standards pending > 720A.
- Motor Over Temperature
- Thyrister Trigger Failure
- Interline Snubber Network
- Zero Speed Detection
- Standstill Logic
- Stall Protection
590+ µðÁöÅÐ DC µå¶óÀ̺ê > 1~2000HP
- 1¿¡¼ 400HP
- UL to 300HP
- »ï»ó ÀÔ·Â
- 230~480V
- Ŭ·¡½Ä ½ºÅ¸ÀÏ
SPECIFICATION
Ratings
Power Configuration | 590+ Four Quadrant Regenerative |
---|---|
2 Fully Controlled Three Phase Thyristor Bridges | |
591+ Two Quadrant Non-Regenerative | |
1 Fully Controlled Three Phase Thyristor Bridges | |
Thyristor Controlled Variable Field Supply | |
Armature Current Ratings(Adc) | 13, 35, 40, 70, 110, 165, 180, 270, 360, 450, 720, 1200, 1700, 2200, 2700A(DRV versions available 1 - 165A) |
Over load(15~450A) : 200% for 10secs, 150% for 30secs | |
Various optinal over load >= 720A | |
Armature Voltage | V armature = Vac x 1.2 |
AC Supply Voltage (Vac) | 110~220V (¡¾10%) |
220~500V (¡¾10%) | |
500~690V (¡¾10%) (>= 200A) | |
ÀÔ·Â Á֯ļö : 50 / 60Hz | |
Field Current | 4A (15~35A Á¤°Ý) |
10A (40~270A Á¤°Ý) | |
20A (360~720A Á¤°Ý) | |
60A (>=1200A Á¤°Ý) | |
ÇʵåÀü¾Ð | V field = Vac x 0.9 |
¾Æ³¯·Î±× ÀÔ·Â | 12ºñÆ® + ½ÅÈ£ ÃÑ 5°³ ÀÔ·Â |
¼Óµµ Áö·ÉÄ¡ 1°³ ÀÔ·Â(-10/0/+10V) | |
º¯°æ °¡´ÉÇÑ 4°³ ÀÔ·Â | |
¾Æ³¯·Î±× Ãâ·Â | 10ºñÆ® ÃÑ 3°³ Ãâ·Â |
¾Æ¸¶Ãß¾î Àü·ù Ãâ·Â 1°³ (-10/0/+10V or 0 -10V) | |
º¯°æ °¡´ÉÇÑ 2°³ Ãâ·Â | |
µðÁöÅÐ ÀÔ·Â | 24vdc ÃÖ´ë ÃÑ 9°³ ÀÔ·Â |
ÇÁ·Î±×·¥ Á¤Áö 1°³ | |
¾ÈÀü Á¤Áö 1°³ | |
¿ÜºÎ Á¤Áö 1°³ | |
°¡µ¿/Á¤Áö 1°³ | |
º¯°æ °¡´ÉÇÑ 5°³ ÀÔ·Â | |
µðÁöÅÐ Ãâ·Â | 3 Total - 24V(max 30V) 100mA |
Short circuit protected | |
3-Configurable | |
Reference Supplies | 1 - +10V dc |
1- -10V dc | |
1- +24V dc | |
Optional Environment | (6051) Operator / Programming Controller |
Feedback Boards : Tachogenerator, Encoder, Glass Fiber Microtach, Plastic Fiber Microtach | |
Serial Communication Technology Box | Profibus DP |
Devicenet | |
Canopen | |
Link | |
EI Bisynch / Modbus / RS422 / RS485 |
Environment
Ambient Operating Temperature | 0~45¡É (15~165A Ratings) |
---|---|
0~30¡É (180~720 A Ratings) | |
0~40¡É (>=1200 A Ratings) | |
Protection | High Energy MOV's |
Instantaneous Over current | |
Inverse Time Over current | |
Field Failure | |
Speed Feedback Failure | |
Motor Over Temperature | |
Thyrister Trigger Failure | |
Interline Snubber Network | |
Zero Speed Detection | |
Standstill Logic, Stall Protection |